Sản phẩm

Slim Photodiode Power Sensors

  • S130
  • 682
  • Liên hệ
  • CONTACT
  • Mô tả chi tiết
  • Thông số kỹ thuật
  • Phần mềm & Driver
  • Tài liệu & Catalogue

Item #a

S130VC

S130C

S132Cb

Aperture Size

Ø9.5 mm

Wavelength Range

200 - 1100 nm

400 - 1100 nm

700 - 1800 nmc

Power Range
(with filter)

500 pW - 0.5 mWd
(Up to 50 mW)d

500 pW - 5 mW
(Up to 500 mW)

5 nW - 5 mW
(Up to 500 mW)

Detector Type

Si Photodiode (UV Extended)

Si Photodiode

Ge Photodiode

Linearity

±0.5%

Resolution

100 pWe

1 nWf

Measurement Uncertaintyg

±3% (440 - 980 nm)
±5% (280 - 439 nm)
±7% (200 - 279 nm, 981 - 1100 nm)

±3% (440 - 980 nm)
±5% (400 - 439 nm)
±7% (981 - 1100 nm)

±5%

Coating/Diffuser

Reflective ND (OD1.5)d

Reflective ND (OD2)i

Absorptive ND (Schott NG9/KG3)c

Housing Dimensions

150 mm x 19 mm x 10 mm; 5 mm Thickness on Sensor Side

Active Detector Area

9.7 mm x 9.7 mm

Cable Length

1.5 m

Mounting Thread

Separate 8-32 and M4 Taps, Posts Not Included

Adapters (Not Included)

SM1A29: Add SM1 Thread and Viewing Target to Aperture
Fiber Adapters Compatible with SM1A29 Adapter: S120-FC, S120-APC, S120-SMA, S120-ST, S120-LC, and S120-SC
FBSM: Integrate Sensor into FiberBench Setups

Compatible Consoles

PM400, PM100D, PM100A, and PM320E

Compatible Interfaces

PM101, PM101A, PM101R, PM101U, PM103, PM103A, PM103U, and PM100USB

  1. For complete specifications, please see the Specs tab.
  2. The minimum measurable power for Germanium photodiodes can vary due to large fluctuations in the sensor's dark current, which is dependent on wavelength and temperature. This is particularly true at the edges of the sensor's operating range where the responsivity is lower.
  3. For the S132C, these specifications are valid for devices with serial numbers 1203xxx or higher. Older versions had a reflective ND diffuser (OD1), which would decrease the wavelength range from 700 nm to 1800 nm to 1200 nm to 1800 nm. For additional information, please contact technical support.
  4. For the S130VC, these specifications are valid for devices with serial numbers 1203xxx or higher. Older versions had an optical power range of 5 nW to 5 mW (50 nW to 50 mW with filter) and a reflective ND diffuser (OD1). For additional information, please contact technical support.
  5. Measured with PM100D console in low bandwidth setting, without filter.
  6. Measured with PM100D console in low bandwidth setting at 1550 nm, without filter.
  7. Beam Diameter > 1 mm.
  8. All sensor responsivities shown in these plots were calibrated to a NIST-traceable source with measurements taken in 5 nm intervals.
  9. For the S130C, these specifications are valid for devices with serial numbers 1203xxx or higher. Older versions had an absorptive ND diffuser (Schott NG9). For additional information, please contact technical support.

Sản phẩm cùng loại

Giá: Liên hệ Mã: OA Series

Thiết bị đo chất lượng chùm tia

Thiết bị đo chất lượng chùm tia

Kiểm tra chất lượng nguồn sáng chính xác nhất

Giá: Liên hệ Mã: FM+

Giá: Liên hệ Mã: M2MS- Series

Dịch vụ & hỗ trợ

Xin hãy vui lòng liên hệ với chúng tôi nếu các bạn có bất kỳ câu hỏi hoặc thắc mắc nào liên quan đến các sản phẩm của Công Ty .